Pengelompokan wilayah dengan menggunakan metode klasifikasi bertujua untuk….

Articles 721 Documents

MEMILIH LOKASI UNTUK BANGUNAN PADA LERENG PERBUKITAN AMAN LONGSOR (STUDY KASUS DI SEKITAR SEMARANG) Lashari, Lashari
Jurnal Teknik Sipil dan Perencanaan Vol 13, No 1 (2011): Jurnal Teknik Sipil & Perencanaan
Publisher : Semarang State University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15294/jtsp.v13i1.1319

Abstract: Building is a place for people to do activities which becomes one of their needs. When desire arises to build at hills, e.g. SekaranGunungpatiSemarang topography, it will be better to be aware of landslide. It is easier if safety criteria is known at hills area. Landslide safety criteria is useful to help the authorized people or the society to choose/use a location at hills/slope with known landslide safety level.Research was done by taking a soil sample 4 m below surface at several location in Sekaran hills. Next, land slide resistance parameter is tested. To observe the structure of lower soil layer a geoelectrical examination data is used. A sliding area model is used for analysis with assumption critical area at hard  soil transition layer is around 3 m below surface.Research shows that Sekaran hills at 21o inclination angle is its critical slope  for landslide. At this angle building construction is not preferable, it will be better for solid vegetation. Safe slope angle for building is below 9o in here. Meanwhile, slope angle between 9o to 21o is still considerable for building by keeping soil water content from saturation through greens, good water channel, and some soil strengthening required.Keywords: slope, landslide, SekaranAbstrak: Bangunan adalah salah satu tempat untuk beraktifitas yang menjadi kebutuhan hidup manusia. Jika keinginan dalam mewujudkan suatu banguan tertuju pada perbukitan, seperti topografi perbukitan Sekaran Gunungpati Semarang, sebaiknya dipersiapkan kecermatan terhadap bahaya longsor. Akan lebih mudah bila di wilayah perbukitan diketahui kreteria keamanan. Kreteria  keamanan longsor dapat bermanfaat untuk membantu pihak yang berkompeten atau masyarakat dalam memilih/menggunakan lokasi perbukitan/lereng dengan diketahui tingkat keamanan longsor. Metode pelaksanaan dilakukan dengan mengambil sampel tanah sedalam 4 m di beberapa titik perbukitan Sekaran. Selanjutnya dilakukan pengujian parameter ketahanan longsor tanah.  Untuk mengetahui struktur lapisan tanah bagian bawah digunakan data penyelidikan geolistrik. Analisis digunakan model sliding area dengan anggapan daerah kritis pada lapisan perubahan tanah keras sedalam berkisar 3 m. Hasil penelitian menunjukkan bahwa perbukitan Sekaran pada kemiringan 21° adalah kemiringan lereng yang mulai tidak aman dari kelongsoran. Kemiringan sebesar ini tidak dianjurkan untuk didirikan bangunan, sebaiknya dimanfaatkan untuk hutan tanaman keras. Kemiringan lereng yang aman untuk didirikan bangunan adalah lereng dibawah kemiringan 9°. Sedangkan Kemiringan lereng dengan kisaran 9° sampai 21°, dapat didirikan bangunan dengan persyaratan mengusahakan kandungan air tanah yang tidak cepat berubah menjadi jenuh, dengan beberapa cara : mempertahankan penghijauan, kelancaran saluran lingkungan, dan beberapa perkuatan tanah yang diperlukan.Kata Kunci: lereng, longsor, Sekaran.

KAJIAN MANAJEMEN OPTIMALISASI PENERANGAN JALAN UMUM KOTA SEMARANG Widodo, Aris
Jurnal Teknik Sipil dan Perencanaan Vol 11, No 1 (2009): Jurnal Teknik Sipil & Perencanaan
Publisher : Semarang State University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15294/jtsp.v11i1.6965

This research mainly aims at giving input to Semarang Local Goverment in the efficiency of electricity utilization to the street illumination and the management of income tax from the societies, so they can be utilized optimally, directedly, and in integrated way in order to the management of city infrastructures service. This research using the influence of traffic passenger car unit (pcu) for optimalizing in a low density of traffic condition. The data of the Average Daily Traffic (ADT) volume on Pahlawan street was gathered from 6.00 p.m-6.00 a.m in every 15 minutes. The data was analyzed using quartil technique with K1 (25%) and K2 (50 %), then the researcher designed a line chart table of a link between the ADT and the time of the electricity switching on. In the working days, it is obtained that (1) the efficient time of street illumination in K1 (25%) was between 10.30 p.m-3.45 a.m, (2) in K2 (50%) was between 9.45 p.m-4.30 a.m. Due to the security and the beauty of the town and also considering the density of the traffic, the optimalization and the dimming of the electricity are not needed in holidays. The optimalization using ballast dimming (40%) from 250 watt to 150 watt for all lamps, obtained a significant account 32,4 Lx for average illumination. It is still fulfill the minimal requirement of 7 Lx for the average illumination on the collector street type. The optimalization with dimming system obtained an efficiency in K1 (25%) was 23.16% and in K2 (50%) was 25,05%. The result of this research can be used as a consideration as well as an input to Semarang Local Goverment for optimalizing illumination street in Semarang.Kajian tentang Manajemen Optimalisasi Penerangan Jalan Umum Kota Semarang dengan Studi kasus di jalan Pahlawan Semarang bertujuan untuk memberi masukan kepada Pemerintah Kota Semarang dalam rangka efisiensi penggunaan daya listrik untuk penerangan jalan umum dan pengelolaan pendapatan pajak dari masyarakat agar dapat digunakan secara terpadu, terarah dan optimal dalam rangka manajemen pelayanan sarana prasaran perkotaan. Kajian ini menggunakan pengaruh dari kepadatan lalu lintas jalan dalam satuan mobil penumpang (smp), guna optimalisasi penerangan jalan umum dalam kondisi kepadatan lalu lintas jalan yang rendah. Data Volume Lalu lintas Harian Rata-rata (LHR) Jalan pahlawan dilakukan dari jam 18.00 sore hari, hingga 06.00 WIB pagi dengan pencatatan per 15 menit, kemudian dibuat tabel grafik garis hubungan antara LHR dengan waktu penyalaan lampu penerangan jalan umum Kota Semarang, pada hari kerja diperoleh : (1) waktu efisiensi penyalaan lampu pada K1 (25%) antara jam 22.30 sampai dengan 03.45 Wib, (2) waktu efisiensi penyalaan lampu pada K2 (50%) antara jam 21.45 sampai dengan 04.30 Wib. Sedangkan pada hari libur berdasarkan keamanan dan keindahan kota serta volume lalulintas kendaraan yang cukup padat maka tidak ada perlakuan optimalisasi peredupan. Optimalisasi dengan sistem peredupan ballast (40%) dari daya 250 watt menjadi 150 watt pada seluruh titik lampu penerangan, didapat perhitungan kuat penerangan rata-rata sebesar 32,4 Lx, dan masih memenuhi syarat minimal kuat penerangan rata-rata untuk jenis jalan kolektor sebesar 7 Lx. Sistem optimalisasi dengan peredupan diperoleh efisiensi pada K1 (25%) sebesar 23,16 % dan K2 (50%) sebesar 25,05%. Hasil persentase optimalisasi penerangan jalan umum di Jalan Pahlawan dapat menjadikan pertimbangan dan masukan bagi Pemerintah Kota Semarang guna melakukan optimalisasi penerangan jalan umum di Kota Semarang.

Ground Vibration Analysis of Railroad Dynamic Loads on Rail Structure Kusumawardani, Rini; Zelin, Mufita Aulia; Kusbiantoro, Arief
Jurnal Teknik Sipil dan Perencanaan Vol 21, No 2 (2019): Jurnal Teknik Sipil & Perencanaan
Publisher : Semarang State University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15294/jtsp.v21i2.20957

The railroad structure consists of rail steel, sleepers, fastening, ballast, sub-ballast and subgrade. The load of the passing train at a certain speed can produce vibrations channeled through the train wheels to the railway steel to be forwarded to the sleepers then to the ballast and distributed to the subgrade. The amount of vibration caused by the train can be seen from the value of the acceleration, amplitude and frequency of the vibration. In this study, the accelerometer sensor was used to detect the magnitude of the vibration acceleration. The vibration acceleration data was then processed using Geopsy software to obtain the value of natural frequency and vibration amplitude using the HVSR (Horizontal to Vertical Spectral Ratio) method. The value of acceleration due to railroad vibration of 0.14 g - 0.64 g with a position placed 1.5 m sensor from the edge of the rail. The biggest vibration acceleration is 0.26 g x direction, 0.39 y direction and 0.29 z direction caused by Maharani trains that pass at a speed of 65 km / h and a load of 728 tons. The natural frequency of vibration obtained value 2.4077 Hz - 5.392 Hz. The highest natural frequency was caused when the Maharani train, which was 5.392 Hz. Train speed and load affected the vibration of the rail structure. The acceleration of vibration increased when the train speed and load increased

TIPOLOGI POLA SPASIAL DAN SEGREGASI SOSIAL LINGKUNGAN PERMUKIMAN CANDI BARU Setyohadi K., Bambang
Jurnal Teknik Sipil dan Perencanaan Vol 9, No 2 (2007): Jurnal Teknik Sipil & Perencanaan
Publisher : Semarang State University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15294/jtsp.v9i2.1612

Settlement environment asthe receptacle of essence societies life is a produce of people culture materialism. Result of tectonies between culture aspect and built environment that's running as comprehensivly. Candi Baru settlement as receptacle of tectonies above full of people culture element in assuming natural condition. Space structure that's unique with social segregation division (elite, neutral, bottom) to be valuable it's era. Space gradation in concept where in the rear of under line settlement in the pattern of 'Kampung Kota" urban city by structured as organic growth. Squares and street, and mass scattered create special built as strongly in the naturalist. Special patterns mention above forming organizational element and structurals in the typology. The meaning of typology is classifications discription of the availability of type. In the element scope that's discripted for classification are two element; special of environmental communal and special of social segregation. Approaching is done by similarity in special visual in the classification of social segregation.Keywords: typology, special pattern, social segregationLingkungan pemukiman sebagai pewadahan harkat kehidupan masyarakat pada essensinya merupakan produk hasil materialisasi budaya masyarakatnya. Hasil olah tektonika antara aspek budaya (culture) dan lingkungan fisik (built enfirontment) yang berjalan secara komprehensif. Pemukiman Candi Baru sebagai hasil olah tektonika tersebut sarat akan pemaknaan unsur budaya masyarakat dalam menyikapi kondisi naturalnya. Pola struktur ruang kawasan yang spesifik (unique) dengan pembagian segregasi sosial (elit, menengah, bawah) menjadi nilai lebih pada jamannya. Konsepsi gradasi ruang, dimana pada bagian belakang pemukiman kelas menengah ini hidup pemukiman kelas bawah dalam bentuk “kampung kota” dengan struktur yang tumbuh secara organis. Ruang-ruang terbuka dan jalan (street and square). Serta sebaran tatanan masa membentuk pola spasial yang kuat dalam sosok bentang alamnya. Pola-pola spasial tersebut membentuk elemen organisasional dan struktural ke dalam tipologi. Yang dimaksud dengan tipologi dalam hal ini adalah deskripsi klasifikasi dari tipe yang ada. Adapun lingkup unsur yang di deskripsikan klasifikasinya adalah dua unsur pokok yaitu pola spasial komunal lingkungan dan pola spasial segregasi sosial. Pendekatan dilakukan melalui kesamaan atau ketunggalrupaan visual spasial dalam satu klasifikasi segregasi sosial.Kata Kunci: tipologi, pola spasial, segregasi sosia

One important factor for development and water resources management is analysis discharge the availability of water.Information about the availability of water can be used for various needs, of them to analyze discharge the availability of water, beforeha Pratiwi, Bertha Silvia
Jurnal Teknik Sipil dan Perencanaan Vol 16, No 1 (2014): Jurnal Teknik Sipil & Perencanaan
Publisher : Semarang State University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15294/jtsp.v16i1.7232

One important factor for development and water resources management is analysis discharge the availability of water.Information about the availability of water can be used for various needs, of them to analyze discharge the availability of water, beforehand kinds of analysese of precipitation data with an analysis of potential evapotranspiration. Flow characteristic Methods and methods of the year the basis of planning ( basic year ) is a step in an analysis discharge andalan (Q80 ).Both of these methods in comparation to determine the amount of water availability in accordance with the state of the watershed of this study. Basic Year which was the year that the reliability of data debit have 80 % ( Q80 ), that is because the risks facing debit of less than discharge mainstay of about 20 % of the number of observationsSalah satu faktor penting untuk pengembangan dan pengelolaan sumber daya air adalah analisis debit ketersediaan air. Informasi mengenai ketersediaan air dapat dimanfaatkan untuk berbagai kebutuhan, diantaranya untuk menganalisis debit ketersediaan air, terlebih dahulu dilakukan analisis data curah hujan dengan analisis evapotranspirasi potensial. Methode flow characteristic dan Metode Tahun Dasar Perencanaan (Basic Year) adalah langkah dalam analisa debit andalan (Q80). Kedua metode tersebut di comparasi untuk menentukan besaran ketersediaan air yang sesuai dengan keadaan DAS studi ini. Tahun dasar yang dipakai adalah tahun yang data debitnya mempunyai keandalan 80% (Q80), yaitu resiko yang dihadapi karena terjadi debit kurang dari debit andalan sebesar 20 % dari jumlah pengamatan. 

PERANCANGAN FASILITAS PEJALAN KAKI DI KORIDOR HIJAU KAMPUS UNIVERSITAS NEGERI SEMARANG Prihanto, Teguh
Jurnal Teknik Sipil dan Perencanaan Vol 14, No 2 (2012): Jurnal Teknik Sipil & Perencanaan
Publisher : Semarang State University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15294/jtsp.v14i2.7098

Universitas Negeri Semarang (Unnes) as The Conservation University will implements the policies of internal transportation which guide movement of users by walking or cycling into campus buildings. Pedestrian facilities is seen fulfills the eligibility and comfort, espescially in the east corridor of campus area. The research objective is to assess the user’s convenience factor and find some alternative facility design concepts of green corridor. Tha variables of study include several aspects: functional, accessible, comfortable and aesthetics. The results showed the the exixting pedestrian still not up to functional standards, both the comfort and safety of users. These can be seen in: open channel which is located on the edge of the pedestrian, cover drain holes at the bottom of an open pedestrian, narrowing pedestrian by other infastructures and trees and lots of pedestrian areas those are not shaded by vegetation shading. Sebagai Kampus Konservasi, Universitas Negeri Semarang (Unnes) akan menerapkan kebijakan transportasi internal yaitu pergerakan pengguna dengan berjalan kaki atau bersepeda menuju gedung kampus. Fasilitas pejalan kaki ini dipandang masih belum memenuhi aspek kelayakan dan kenyamanan, terutama di koridor kawasan kampus timur. Tujuan penelitian adalah mengkaji faktor kenyamanan pengguna dan menemukan alternatif konsep perancangan fasilitas koridor hijau di kawasan kampus timur. Variabel penelitian meliputi aspek: fungsional, aksesibel, kenyamanan dan estetika. Dari hasil penelitian menunjukkan bahwa Pedestrian yang ada masih belum mencapai standar fungsional, baik kenyamanan maupun keamanan pengguna. Hal ini dapat dilihat pada: saluran terbuka yang berada tepat di sisi tepi pedestrian, penutup lubang saluran di bawah pedestrian yang terbuka, penyempitan pedestrian oleh prasaraana lain dan pohon dan banyak area pedestrian yang tidak ternaungi oleh vegetasi peneduh

PENGAWETAN KAYU SENGON MELALUI RENDAMAN DINGIN MENGGUNAKAN BAHAN PENGAWET ENBOR SP DITINJAU TERHADAP SIFAT MEKANIK Pangestuti, Endah Kanti; Lashari, Lashari; Hardomo, Agus
Jurnal Teknik Sipil dan Perencanaan Vol 18, No 1 (2016): Jurnal Teknik Sipil & Perencanaan
Publisher : Semarang State University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15294/jtsp.v18i1.6695

The use of wood in construction world continues to increase both for the use of structural and non-structural. Needs a very large timber impact on the availability of wood shrinks every year as a result of exploitation by large scale. One attempt to extend the service life of wood is the wood preservation. This study aims to determine mechanical properties of wood by soaking sengon due to cold preservation with preservative EnborSP. The method used is the method of experiments carried out in the Laboratory of Materials of Civil Engineering, Faculty of Engineering, State University of Semarang. The preservation process used isa process with a cold soaking method, with a preservative solution EnborSP with a concentration of 0%, 3%, 6% and 9%. The response observed was the value-the value retention of preservatives, and mechanical properties (compressive strength of parallel fiber direction, flexural strength and surface hardness) of wood. Preservation method applied is cold soaking (for 5 days or 120 hours). Average retention value-average increase of 2.57kg/m3 (3%), 4.89kg/m3 (6%), and 6.74kg/m3 (9%). Value - average compressive strength of parallel to the direction of the wood fiber sengon increase of 149.39kg/cm2 (0%), 156.35kg/cm2 (3%), 187.80kg/cm2 (6%), and 216, 44kg/cm2 (9%). Value – average flexural strength sengon increase of 175.36kg/cm2 (0%), 202.55kg/cm2 (3%), 272.64kg/cm2 (6%), and 362.81kg/cm2 (9%). Value – average penetration sengon wood decreased from 0.93cm (0%), 0.67cm (3%), 0.57cm (6%), and 0.43cm (9%). This decrease shows that there is an increase in the value of the wood sengon surface hardness. Salah satu usaha untuk memperpanjang umur pemakaian kayu adalah dengan pengawetan kayu. Penelitian ini bertujuan untuk mengetahui sifat mekanik kayu sengon akibat pengawetan secara rendaman dingin dengan bahan pengawet Enbor SP. Metode penelitian yang digunakan adalah metode eksperimen yang dilakukan di Laboratorium Bahan dan Laboratorium Kerja Kayu Teknik Sipil Fakultas Teknik Universitas Negeri Semarang. Proses pengawetan yang digunakan adalah proses dengan metode rendaman dingin, dengan larutan bahan pengawet Enbor SP dengan konsentrasi 0 %, 3 %, 6 %, dan 9 %. Respon yang diamati adalah nilai – nilai retensi bahan pengawet dan serta sifat mekanis (kuat tekan tekan sejajar arah serat, kuat  lentur dan kekerasan permukaan) kayu. Metode pengawetan yang diterapkan adalah rendaman dingin (selama 5 hari atau 120 jam). Nilai retensi rata – rata mengalami kenaikan dari 2,57 kg/m3 (3 %), 4,89 kg/m3 (6 %), dan 6,74 kg/m3 (9 %). Nilai rata – rata kekuatan tekan sejajar arah serat kayu sengon mengalami kenaikan dari 149,39 kg/cm2 (0 %), 156,35 kg/cm2 (3 %), 187,80 kg/cm2 (6 %), dan 216,44 kg/cm2 (9 %). Nilai rata – rata kekuatan lentur kayu sengon mengalami kenaikan dari 175,36 kg/cm2 (0 %), 202,55 kg/cm2 (3 %), 272,64 kg/cm2 (6 %), dan 362,81 kg/cm2 (9%). Nilai rata – rata penembusan kayu sengon menurun dari 0,93 cm (0 %), 0,67 cm (3 %), 0,57 cm (6 %), dan 0,43 cm (9 %). Penurunan ini memperlihatkan bahwa ada peningkatan nilai kekerasan permukaan kayu sengon.

FAKTOR-FAKTOR YANG BERPERAN TERHADAP PENINGKATAN SIKAP KESELAMATAN DAN KESEHATAN KERJA (K3) PARA PELAKU JASA KONSTRUKSI DI SEMARANG Endroyo, Bambang
Jurnal Teknik Sipil dan Perencanaan Vol 12, No 2 (2010): Jurnal Teknik Sipil & Perencanaan
Publisher : Semarang State University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15294/jtsp.v12i2.1344

Abstract: Implementation of Occupational Health and Safety (K3), especially in the construction sector was still bad. K3 in Indonesia is have the lowest rank in Asean. Various efforts have been made by government to reduce occupational accidents to a minimum as possible. Accidents often occur were mostly caused by human factors,  about 85%. Construction Safety Implementation in the field depends on the attitude and the behavioral of the participant of construction services. The attitude of K3 depends on many factors, among others - which will be studied through this research - are: education, experience, certification, and corporate commitment. From these various factors, educational factors correlated 0.30 (significance: 0.048) contribute to attitude of K3 , and was another factor correlations were not significant. All these factors have  only to give efectif contribution about to 0.213 (21.3%) of the attitude factor K3. It means that about of  78.7% hich can not be explained and is a problem to be studied again. Key words: attitude of K3, construction, participant of construction services  Abstrak:   Pelaksanaan Keselamatan dan Kesehatan Kerja (K3) terutama di sektor konstruksi masih memprihatinkan. K3 di Indonesia masih menduduki urutan terbawah di Asean. Berbagai upaya telah dilakukan oleh pemerintah untuk menekan kecelakaan kerja menjadi se minimal mungkin. Kecelakaan yang sering terjadi banyak diakibatkan oleh faktor manusia (human factor) yaitu sebesar 85%. Pelaksanaan K3 Konstruksi di lapangan sangat tergantung dari sikap dan perilaku para pelaku jasa konstruksi. Sikap K3 sangat tergantung dari banyak faktor, antara lain yang akan diungkap melalui penelitian ini adalah: pendidikan, pengalaman, sertifikasi, dan komitmen perusahaan. Dari berbagai faktor tersebut, faktor pendidikan mempunyai korelasi ,30 (signifikansi: 0,048) terhadap sikap K3, sedang faktor lainnya korelasinya tidak signifikan. Semua faktor tersebut hanya memberi memiliki sumbangan efektif sebesar 0,213 (21,3%) terhadap faktor sikap K3.   Hal itu menunjukkan bahwa masih ada   78,7 % yang belum dapat dijelaskan dan merupakan masalah yang masih harus diupayakan jawabnya. Kata kunci: sikap K3, konstruksi, pelaku jasa konstruksi

SINERGI PENGGUNAAN CALCIUM STEARATE DAN FLY ASH DALAM BETON UNTUK MENAHAN TEKANAN AIR Maryoto, Agus
Jurnal Teknik Sipil dan Perencanaan Vol 16, No 2 (2014): Jurnal Teknik Sipil & Perencanaan
Publisher : Semarang State University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15294/jtsp.v16i2.7215

Reinforced concrete structure located in corrosive environment and withstand the water pressure is very prone to corrosion attack. The waterinfiltrate to the concrete through the capillaries that are formed during the process of hardening concrete can only be reduced by decreasing the diameter of the micro-capillary. Increasing the contact angle between the water and the concrete surface is also able to reduce the infiltration of water into the concrete. fly ash is a material that has a smaller grain than cement. After the fly ash reacts with cement and water, forming of micro capillary diameter becomes smaller. Calcium stearate is used as an ingredient in making concrete the concrete surface becomes more hydrophobic. Tests were conducted to determine the effect of calcium stearate and fly ash namely compressive strength test, absorption and penetration. The results showed that the use of fly ash and calcium atearate together in the concrete can decrease the value of the absorption and penetration.Struktur beton bertulang yang terletak di daerah korosif dan menahan tekanan air sangat rawan terhadap serangan korosi. Tekanan air yang masuk ke dalam beton melalui kapiler yang terbentuk pada saat proses pengerasan beton hanya bisa dikurangi dengan memperkecil diameter mikro kapiler. Peningkatan sudut kontak antara air dan permukaan beton juga mampu menurunkan infiltrasi air ke dalam beton. Fly ash merupakan material yang mempunyai butir yang lebih kecil dari semen. Setelah fly ash bereaksi dengan semen dan air diameter mikro kapiler yang terbentuk menjadi lebih kecil. Calcium stearate yang digunakan sebagai campuran dalam beton membuat permukaan beton menjadi lebih bersifat hydrophobic. Pengujian yang dilakukan untuk mengetahui pengaruh calcium stearate dan fly ash yaitu uji kuat tekan, absorbsi dan penetrasi. Hasil penelitian menunjukkan bahwa penggunaan calcium stearate dan fly ash secara bersama-sama di dalam beton mampu menurunkan nilai absorbsi dan penetrasi.

TIPOLOGI RUMAH SUSUN DI KOTA YOGYAKARTA Mulyandari, Hestin
Jurnal Teknik Sipil dan Perencanaan Vol 14, No 2 (2012): Jurnal Teknik Sipil & Perencanaan
Publisher : Semarang State University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15294/jtsp.v14i2.7089

Yogyakarta city did not escape from the slums. Some ways of thinking to solve the problem, including the construction of flats, the residents are expected to have a more decent place to live as well as efforts to curb the city. This study aims to analyze the typology of the three flats in the Municipality of Yogyakarta, in order to know the advantages and disadvantages of physical, inconvenience users of flats, which will produce a number of recommendations to guide the planning and design of the new flats.Research carried out by using the Post Occupancy Evaluation (POE) in terms of physical control and functional frame.Physical aspects of the typology analysis of control: (1) control the climate, the average flats does not have adequate shading so it can not avoid the rain, (2) the problem of waste and storm sewers are clogged, causing a stench, (3) using tile metal roofing is not sandy so hot during the day for a stay on the top floor, and when the rain came a loud voice from the rain. Analysis of the functional frame (1) the average pattern of the building are single loaded, 2) in the towers have the same type, (3) the height of the floor for the towers Jogoyudan and Juminahan is 3 m, while the towers Cokrodirjan is 2.8 m. Efforts to add new towers to accommodate the people who still live on the banks of the river was still hazardous Code of cold lava.Kota Yogyakarta tidak luput dari  pemukiman kumuh. Rumah-rumah di sekitar bantaran Sungai Code saling berhumpitan. Dari sinilah mulai timbul cara memecahkan masalah tersebut, diantaranya adalah pembangunan rumah susun, yang diharapkan warga mempunyai tempat tinggal yang lebih layak sekaligus sebagai upaya penertiban kota. Penelitian ini bertujuan untuk menganalisa tipologi terhadap tiga rusunawa di Kotamadya Yogyakarta, untuk dapat mengetahui keunggulan dan kelemahan fisik, ketidaknyamanan pengguna rusunawa, sehingga akan menghasilkan beberapa rekomendasi sebagai pedoman perencanaan dan perancangan rumah susun yang baru nantinya. Penelitian dilakukan dengan kajian Evaluasi Purna Huni (EPH) dari segi physical control dan functional framenya. Analisa tipologi dari aspek Physical control yaitu (1) kontrol terhadap iklim, rata-rata rusunawa tidak memiliki tritisan yang memadai sehingga tampias hujan; (2) masalah sampah dan saluran air kotor yang mampet, menimbulkan bau menyengat; (3) penutup atap menggunakan genteng metal yang tidak berpasir sehingga panas di siang hari untuk yang tinggal di lantai teratas, dan apabila hujan terdengar suara keras dari air hujan. Analisa dari functional frame (1) rata-rata pola bangunan single loaded; (2) dalam satu rusun memiliki besaran unit yang sama; (3) ketinggian lantai untuk rusun Juminahan dan Jogoyudan 3 m, sedangkan rusun Cokrodirjan 2,8 m. Upaya menambah rusun yang baru untuk mewadahi masyarakat yang masih tinggal di tepi sungai Code yang masih rawan bahaya lahar dingin.